Recent studies3 have shown that TCD studies have greater sensitivity and accuracy than conventional TEE or TTE testing. TCD studies have been reported to have a sensitivity of 98% whereas the sensitivity for TEE is 91% and TTE is 64%. Accuracy for these TCD studies has been reported at 94% while for TEE it is 88% and for TTE it is 63%. TCD has been shown to detect smaller right-left shunts than possible with TEE.
Since 1979, the team of scientists and engineers at Multigon Industries have been providing the medical community with innovative diagnostic tools. In the early 1980’s Rune Aaslid developed the first Transcranial Doppler using the Multigon Angioscan Doppler spectrum analyzer. The Brainvue-TCD 1000 Series represents the culmination of years of innovation, research, and interaction with clinicians. Experience the Brainvue-TCD 1000 designed with the clinical setting in mind.
APPLICATIONS
- Evaluation of intracranial effects of extracranial stenosis, including assessment of collateral flow pathways
- Quick assessment of the MCA’s, PCA’s and Basilar artery for over/under interpreted MRA’s
- Detection and monitoring of vasospasm following aneurysmal subarachnoid hemorrhage
- Evaluation and monitoring of intracranial blood flow during surgical procedures
- Detection of PFO (patent foramen ovale) with few ancillary supplies
- Clotbusting: helps catalyze thrombolysis in the acute stroke patient1
- Evaluation of vasomotor reserve (CO2 Reactivity)
- Emboli detection and monitoring of embolic events
- Diagnosis of intracranial stenosis and occlusion
- Identification of feeder arteries in AVM’s
- Supports the diagnosis of brain death
- Screening for basilar artery stenosis
- Management of sickle cell disease
- Vascular interventional procedures: monitoring during carotid stent placement or testing balloon occlusion
- Trend analysis of daily vasospasm testing
PRINTABLE REPORTS
Easily create professional reports in multiple formats. Display exam results with selected vessel graphics and in text only format.
FILE STORAGE
The Brainvue-TCD 1000 file storage system provides printing and archiving of the full patient report. Upon completion of the examination, simply click on the save button and all of the study information is stored in the TCD patient database. Review, post process, and playback stored files on the Brainvue-TCD 1000 In addition files may also be archived to various removable media including CD-ROM, DVD, and optional DICOM output.
PORTABILITY
Lightweight and compact, the Brainvue-TCD 1000 provides the ultimate experience in portability. For use in hospitals, private offices, mobile services, and clinics.
TRAINING
Fee based training available in clinical setting.